{"id":10734,"date":"2026-11-26T13:58:33","date_gmt":"2026-11-26T05:58:33","guid":{"rendered":"https:\/\/www.yantaisensor.com\/?p=10734"},"modified":"2026-11-26T14:15:29","modified_gmt":"2026-11-26T06:15:29","slug":"how-to-choose-a-pyranometer","status":"publish","type":"post","link":"https:\/\/www.yantaisensor.com\/vi\/blog\/how-to-choose-a-pyranometer","title":{"rendered":"C\u00e1ch l\u1ef1a ch\u1ecdn m\u00e1y \u0111o t\u1ed5ng b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi cho c\u00e1c d\u1ef1 \u00e1n \u0111i\u1ec7n m\u1eb7t tr\u1eddi"},"content":{"rendered":"<style>.postid-10734 .wp-block-table{overflow-x:auto;-webkit-overflow-scrolling:touch}.postid-10734 .wp-block-table table{min-width:620px}.postid-10734 .wp-block-table th,.postid-10734 .wp-block-table td{word-break:normal;overflow-wrap:normal}<\/style>\n\n\n\n<p class=\"wp-block-paragraph\">When choosing a pyranometer for solar projects, EPC contractors and procurement teams often find that products with similar specifications are not necessarily suitable for the same application. A project may require plane-of-array (POA) irradiance measurements, while a supplier offers a sensor designed primarily for global horizontal irradiance (GHI). In other cases, the measurement range or accuracy may meet the initial requirements, but the output signal is incompatible with the existing data logger. These differences can affect system integration, data reliability, and the overall cost of the monitoring setup.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So, how to choose a pyranometer that fits the actual project requirements? The decision should start with the intended measurement and the monitoring requirements, rather than price or a single accuracy figure. This guide explains the key factors to consider when evaluating a pyranometer for solar projects, helping buyers assess whether a sensor&#8217;s performance, specifications, and installation requirements match the intended application.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"576\" data-id=\"6466\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/04\/Pyranometer-Installation-Guide.webp\" alt=\"H\u01b0\u1edbng d\u1eabn l\u1eafp \u0111\u1eb7t m\u00e1y \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi\" class=\"wp-image-6466\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/04\/Pyranometer-Installation-Guide.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/04\/Pyranometer-Installation-Guide-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/04\/Pyranometer-Installation-Guide-16x12.webp 16w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"5929\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14.webp\" alt=\"M\u00e1y \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi d\u00f9ng trong nghi\u00ean c\u1ee9u n\u00f4ng nghi\u1ec7p\" class=\"wp-image-5929\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14-16x12.webp 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Define Your Solar Project&#8217;s Irradiance Measurement Requirements<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Start pyranometer selection by clarifying what the project needs to learn from its irradiance data. During site development, measurements help assess the available solar resource and support energy yield estimates. Once a PV plant is operating, the focus shifts to the radiation received by the modules and its relationship with actual power generation. These different objectives influence the type of irradiance information the monitoring system needs to collect.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Solar Resource Assessment vs. PV Performance Monitoring<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For solar resource assessment, the priority is to understand the site&#8217;s solar conditions over time. Irradiance data helps project developers evaluate solar availability, seasonal variations, and the potential energy yield before committing to a project. The measurements should provide a reliable picture of the site&#8217;s resource conditions rather than simply record short-term weather changes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PV performance monitoring serves a different purpose. After commissioning, operators need to understand how changes in sunlight affect the plant&#8217;s power output. Irradiance measurements provide the environmental reference for evaluating module performance under actual operating conditions. The focus is therefore on the radiation reaching the PV array and how well the collected data reflects the conditions experienced by the monitored modules.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These applications are closely related, but their measurement objectives are not identical. Resource assessment examines the site&#8217;s solar potential, while operational monitoring helps explain how the installed system performs under the available sunlight.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How PV System Design Affects Irradiance Measurement Requirements<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Array layout and operating method also affect solar pyranometer selection. A sensor arrangement suitable for a fixed-tilt installation may not represent the conditions experienced by a tracking or bifacial array.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Trang tr\u1ea1i n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi quy m\u00f4 ti\u1ec7n \u00edch:<\/strong> Large sites may contain different terrain, array orientations, and local shading conditions. Measurement points need to represent the monitored sections of the plant; a single reading should not automatically be treated as representative of the entire site.<\/li>\n\n\n\n<li><strong>Commercial and rooftop PV systems:<\/strong> Roof orientation, module tilt, surrounding buildings, and available installation space affect the conditions around the array. Measurements should reflect the actual module layout rather than an unrelated open area on the roof.<\/li>\n\n\n\n<li><strong>Solar tracking systems:<\/strong> The modules change their position throughout the day. The project must account for this movement when deciding whether measurements should represent the changing module plane or a separate reference plane.<\/li>\n\n\n\n<li><strong>H\u1ec7 th\u1ed1ng PV hai m\u1eb7t:<\/strong> Both module surfaces contribute to energy generation. In addition to front-side irradiance, the monitoring objective may require information about rear-side radiation and reflected sunlight from the ground.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These project differences define the measurement scope for pyranometer selection. They also help determine whether the monitoring setup needs a standalone pyranometer or a more integrated arrangement. The next step is to examine the instrument classifications and standards against the project&#8217;s documented requirements.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-2 wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"3567\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-6.webp\" alt=\"Thi\u1ebft b\u1ecb \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi \u0111\u01b0\u1ee3c l\u1eafp \u0111\u1eb7t b\u00ean c\u1ea1nh m\u00f4-\u0111un quang \u0111i\u1ec7n\" class=\"wp-image-3567\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-6.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-6-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-6-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"3566\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-5.webp\" alt=\"Thi\u1ebft b\u1ecb gi\u00e1m s\u00e1t th\u1eddi ti\u1ebft \u0111\u01b0\u1ee3c l\u1eafp \u0111\u1eb7t b\u00ean c\u1ea1nh d\u00e0n pin quang \u0111i\u1ec7n\" class=\"wp-image-3566\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-5.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-5-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-5-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Understand Pyranometer Accuracy Classes and Industry Standards<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 9060:2018 classifies pyranometers according to their measurement performance. IEC 61724-1:2021 specifies irradiance sensor requirements for PV monitoring systems. For pyranometer selection, the two standards address different aspects of measurement and should not be treated as interchangeable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What Do Class A, Class B, and Class C Mean Under ISO 9060?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 9060:2018 divides pyranometers into three performance classes: Class A, Class B, and Class C. Class A has the strictest requirements, followed by Class B and Class C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For pyranometer selection, review the performance parameters behind each class:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Th\u1eddi gian ph\u1ea3n h\u1ed3i:<\/strong> How quickly the sensor responds to changes in irradiance.<\/li>\n\n\n\n<li><strong>Zero Offset:<\/strong> Unwanted output under zero irradiance conditions.<\/li>\n\n\n\n<li><strong>Non-Stability:<\/strong> Changes in sensor sensitivity over time.<\/li>\n\n\n\n<li><strong>Non-Linearity:<\/strong> Deviation from a linear response across the measurement range.<\/li>\n\n\n\n<li><strong>Directional Response:<\/strong> Changes in response as the angle of incoming radiation varies.<\/li>\n\n\n\n<li><strong>Temperature Response:<\/strong> Output variation caused by ambient temperature changes.<\/li>\n\n\n\n<li><strong>Spectral Error:<\/strong> Differences between the sensor&#8217;s spectral response and the reference spectrum.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These parameters are assessed together to determine the instrument&#8217;s class. Class A does not represent a fixed accuracy of \u00b11%, and Class B does not automatically mean \u00b12%. Each parameter has its own performance limits.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How IEC 61724-1 Defines Irradiance Sensor Requirements<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEC 61724-1:2021 sets different pyranometer requirements for Class A and Class B PV monitoring systems. The required instrument class also depends on whether irradiance is measured on the front or rear side of a bifacial array.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Monitoring application<\/th><th>Pyranometer requirement<\/th><\/tr><\/thead><tbody><tr><td>Class A system, front-side POA\/GHI<\/td><td>ISO 9060 Class A, spectrally flat; calibration uncertainty \u22642%<\/td><\/tr><tr><td>Class A system, rear-side<\/td><td>ISO 9060 Class C or better; calibration uncertainty \u22643%<\/td><\/tr><tr><td>Class B system<\/td><td>ISO 9060 Class C or better; calibration uncertainty \u22643%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For these measurements, the standard specifies calibration uncertainty at 1,000 W\/m\u00b2, a measurement range up to 1,500 W\/m\u00b2, and resolution of 1 W\/m\u00b2 or better.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This distinction matters in pyranometer selection. A Class A PV monitoring system does not require every irradiance sensor to be ISO 9060 Class A. The required instrument class depends on its measurement position and application. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a closer comparison of the two higher classes, see <a href=\"https:\/\/www.yantaisensor.com\/vi\/blog\/class-a-vs-class-b-pyranometers\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">Nh\u1eadt x\u1ea1 k\u1ebf C\u1ea5p A so v\u1edbi C\u1ea5p B: B\u1ea1n c\u1ea7n lo\u1ea1i n\u00e0o?<\/mark><\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-3 wp-block-gallery-3 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"5932\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-17.webp\" alt=\"How to choose a pyranometer: two instruments installed side by side outdoors\" class=\"wp-image-5932\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-17.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-17-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-17-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-17-16x12.webp 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"3569\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-8.webp\" alt=\"Weather and irradiance monitoring equipment at a PV installation\" class=\"wp-image-3569\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-8.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-8-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-8-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"900\" data-id=\"3335\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-16.webp\" alt=\"Close-up of a pyranometer glass dome and sensing surface\" class=\"wp-image-3335\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-16.webp 1200w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-16-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-16-1024x768.webp 1024w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-16-768x576.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Thermopile vs. Silicon Pyranometers: Which Technology Fits Your Project?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Thermopile and silicon pyranometers differ in spectral response, response time, and measurement characteristics. Pyranometer selection depends on the required irradiance measurement and how the data will be used in your solar project.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Differences Between Thermopile and Silicon Sensors<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>So s\u00e1nh<\/th><th>Pyranometer Thermopile<\/th><th>Silicon-Based Sensor<\/th><\/tr><\/thead><tbody><tr><td>Nguy\u00ean l\u00fd \u0111o l\u01b0\u1eddng<\/td><td>Measures absorbed solar radiation through a thermopile<\/td><td>Converts incident light into an electrical signal using a silicon photodiode<\/td><\/tr><tr><td>\u0110\u00e1p \u1ee9ng ph\u1ed5<\/td><td>Broad response, typically around 0.3\u20133.2 \u03bcm, depending on the model<\/td><td>Narrower response, limited by the photodiode&#8217;s spectral sensitivity<\/td><\/tr><tr><td>Th\u1eddi gian ph\u1ea3n h\u1ed3i<\/td><td>Th\u01b0\u1eddng ch\u1eadm h\u01a1n<\/td><td>Th\u01b0\u1eddng nhanh h\u01a1n<\/td><\/tr><tr><td>Temperature effects<\/td><td>Temperature response needs to be considered<\/td><td>Temperature compensation is important<\/td><\/tr><tr><td>\u1ee8ng d\u1ee5ng \u0111i\u1ec3n h\u00ecnh<\/td><td>Broadband solar irradiance and meteorological measurements<\/td><td>Fast irradiance measurements and PV reference applications<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Pyranometer Selection by Sensor Technology<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>For broadband solar radiation measurement:<\/strong> A thermopile pyranometer is generally more suitable for solar resource assessment and long-term irradiance monitoring.<\/li>\n\n\n\n<li><strong>For fast-response measurements:<\/strong> A silicon-based solar irradiance sensor may be appropriate. For PV reference measurements, check its spectral match with the module technology.<\/li>\n\n\n\n<li><strong>For integrated PV monitoring:<\/strong> Check whether the system measures the required POA irradiance and provides the environmental parameters needed for performance analysis.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The Yantai Sensor <a href=\"https:\/\/www.yantaisensor.com\/vi\/san-pham\/compact-weather-sensor-for-solar\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">XF500S-CWB<\/mark><\/a> combines POA irradiance measurement with environmental and module temperature monitoring. Its standard configuration uses a TBQ-2C-D thermopile sensor, making it an example of an integrated PV weather sensor based on thermopile measurement technology.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The technology comparison in <a href=\"https:\/\/www.yantaisensor.com\/vi\/blog\/thermopile-vs-silicon-pyranometer\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">Nhi\u1ec7t \u0111i\u1ec7n tr\u1edf so v\u1edbi Quang \u0111i\u1ec7n tr\u1edf Silicon: \u01afu v\u00e0 Nh\u01b0\u1ee3c \u0111i\u1ec3m<\/mark><\/a> provides more detail on spectral response and measurement applications.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-4 wp-block-gallery-4 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"5916\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-3.webp\" alt=\"White diffuser solar irradiance sensor with a wired connector\" class=\"wp-image-5916\" style=\"aspect-ratio:1\/1;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-3.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-3-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-3-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-3-16x12.webp 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"5917\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-4.webp\" alt=\"Glass-dome pyranometer with its connection cable\" class=\"wp-image-5917\" style=\"aspect-ratio:1\/1;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-4.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-4-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-4-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-4-16x12.webp 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"900\" data-id=\"3330\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-6.webp\" alt=\"Top view of a white diffuser solar irradiance sensor\" class=\"wp-image-3330\" style=\"aspect-ratio:1\/1;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-6.webp 1200w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-6-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-6-1024x768.webp 1024w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-6-768x576.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"900\" data-id=\"3329\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-5.webp\" alt=\"Top view of a glass-dome pyranometer\" class=\"wp-image-3329\" style=\"aspect-ratio:1\/1;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-5.webp 1200w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-5-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-5-1024x768.webp 1024w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-5-768x576.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Choose the Right Irradiance Measurement: GHI, POA, DHI, or DNI<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Solar pyranometer selection starts with the measurement target. Global Horizontal Irradiance (GHI) measures total radiation on a horizontal surface, while Plane of Array (POA) irradiance measures radiation received by the PV module plane. Diffuse Horizontal Irradiance (DHI) and Direct Normal Irradiance (DNI) separate diffuse and direct solar radiation. The required solar irradiance measurements depend on the project&#8217;s monitoring objectives, array design, and performance evaluation needs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">C\u01b0\u1eddng \u0111\u1ed9 b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi ngang to\u00e0n c\u1ea7u (GHI)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GHI measures the total solar radiation received by a horizontal surface, including the horizontal component of direct sunlight and diffuse radiation from the sky. It is commonly used for solar resource assessment, site evaluation, and meteorological monitoring. For GHI measurements, pyranometer selection must allow horizontal installation and proper leveling. GHI cannot directly replace POA measurements when PV modules are installed at a tilt, because the two measurements represent different irradiance planes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Plane of Array (POA) Irradiance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">POA irradiance measures solar radiation received on a surface aligned with the PV module plane. It provides a more direct reference for evaluating the irradiance available to the modules than horizontal GHI. Pyranometer selection must allow installation suited to the array design:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>PV system<\/th><th>POA sensor installation<\/th><\/tr><\/thead><tbody><tr><td>Fixed-tilt system<\/td><td>Match the sensor&#8217;s tilt and orientation to the module array. A separate mounting bracket can be used; direct attachment to a module is not necessary.<\/td><\/tr><tr><td>Tracking system<\/td><td>If the objective is to measure irradiance on the moving module plane, the sensor should follow the tracker&#8217;s changing position.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Diffuse Horizontal Irradiance (DHI) and Direct Normal Irradiance (DNI)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">DHI measures diffuse solar radiation received by a horizontal surface, excluding direct sunlight. It is typically measured using a pyranometer with a shading device, such as a shading ball or ring, to block the direct solar beam. Depending on the device and measurement method, corrections may be needed to account for the portion of the sky obscured by the shading device.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DNI measures direct solar radiation on a surface perpendicular to the sun&#8217;s rays. It is generally measured using a <a href=\"https:\/\/gml.noaa.gov\/grad\/instruments.html\" target=\"_blank\" rel=\"noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">m\u00e1y \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi<\/mark><\/a> mounted on a solar tracker that follows the sun. A standard pyranometer cannot directly replace this setup because it does not independently measure the direct solar beam.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The relationship between these three measurements is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>GHI = DHI + DNI \u00d7 cos(\u03b8<sub>z<\/sub>)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Here, \u03b8<sub>z<\/sub> represents the solar zenith angle. Separate DHI and DNI measurements are useful for detailed solar resource assessment and radiation analysis, but they are not automatically required for routine PV performance monitoring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The individual radiation components are explained in <a href=\"https:\/\/www.yantaisensor.com\/vi\/blog\/ghi-vs-dni-vs-dhi-explained\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">GHI, DNI v\u00e0 DHI trong n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi l\u00e0 g\u00ec?<\/mark><\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Irradiance Measurements for Bifacial PV Systems<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bifacial modules receive solar radiation from both front and rear surfaces, so front-side POA alone may not fully represent the irradiance conditions affecting the modules. A more complete measurement setup may include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Front-side POA irradiance:<\/strong> Measures radiation received by the front surface of the modules.<\/li>\n\n\n\n<li><strong>Rear-side irradiance:<\/strong> Measures radiation reaching the back of the modules. The sensor should be positioned parallel to the module rear surface at a representative location, away from local obstructions.<\/li>\n\n\n\n<li><strong>Albedo measurement:<\/strong> Evaluates ground reflectance by comparing incoming and reflected solar radiation under suitable measurement conditions. Ground materials such as soil, gravel, concrete, and snow can affect the result.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Albedo and rear-side irradiance are not interchangeable. Albedo describes ground reflectance, while rear-side irradiance measures the radiation reaching the module&#8217;s back surface. Rear-side readings also depend on array height, row spacing, module geometry, shading, and sensor position. Multiple measurement points may be needed to represent variations across a bifacial array.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-2 wp-block-gallery-5 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" data-id=\"5929\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14-300x225.webp\" alt=\"Two irradiance sensors mounted on an outdoor monitoring platform\" class=\"wp-image-5929\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14-16x12.webp 16w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-14.webp 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" data-id=\"5928\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-13-300x225.webp\" alt=\"C\u1ea3m bi\u1ebfn \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi d\u00f9ng trong gi\u00e1m s\u00e1t m\u00f4i tr\u01b0\u1eddng\" class=\"wp-image-5928\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-13-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-13-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-13-16x12.webp 16w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-13.webp 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Specifications to Check Before Buying a Pyranometer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The next step in pyranometer selection is to compare the specifications of models that meet the measurement requirements. The following four areas help determine whether a pyranometer is suitable for the project and compatible with its monitoring system.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Pyranometer selection criteria<\/th><th>Key specifications<\/th><th>What to verify<\/th><\/tr><\/thead><tbody><tr><td>Measurement performance<\/td><td>Measurement range, sensitivity, spectral response<\/td><td>Confirm that the range and spectral response suit the measurement objective, and that the output signal can be properly acquired.<\/td><\/tr><tr><td>Response characteristics<\/td><td>Response time, temperature response, cosine response<\/td><td>Check how the sensor performs under changing irradiance, ambient temperatures, and different solar angles.<\/td><\/tr><tr><td>Calibration and stability<\/td><td>Calibration uncertainty, long-term stability, calibration documentation<\/td><td>Verify calibration traceability, measurement uncertainty, stability specifications, and available calibration documents.<\/td><\/tr><tr><td>Electrical compatibility<\/td><td>Output signal, communication protocol, power supply, data logger input<\/td><td>Confirm that the sensor&#8217;s electrical output and communication settings match the data acquisition system.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Pyranometer selection requires checking these specifications together rather than comparing them individually. A pyranometer may meet the required measurement performance but still cause integration problems if its output, power supply, or calibration documentation does not meet project requirements.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-3 wp-block-gallery-6 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"900\" data-id=\"3334\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-15.webp\" alt=\"Close-up of the electrical connector on a pyranometer housing\" class=\"wp-image-3334\" style=\"aspect-ratio:1\/1;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-15.webp 1200w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-15-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-15-1024x768.webp 1024w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-15-768x576.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" data-id=\"3597\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-17.webp\" alt=\"Solar radiation sensor with a wired output connector\" class=\"wp-image-3597\" style=\"aspect-ratio:1\/1;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-17.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-17-300x300.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-17-150x150.webp 150w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-17-768x768.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"900\" data-id=\"3336\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-17.webp\" alt=\"Underside of a pyranometer showing mounting points\" class=\"wp-image-3336\" style=\"aspect-ratio:1\/1;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-17.webp 1200w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-17-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-17-1024x768.webp 1024w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-17-768x576.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Installation and Environmental Conditions That Affect Pyranometer Performance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Installation conditions are part of solar pyranometer selection and affect the reliability of irradiance data. Even a suitable sensor can produce misleading readings if its measurement angle, installation position, or outdoor conditions are not properly considered.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mounting Position, Tilt, and Orientation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The mounting angle depends on the irradiance being measured. A GHI pyranometer should be installed horizontally and leveled, while a POA sensor should match the tilt and azimuth of the PV modules.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For fixed arrays, an independent bracket can be used if it maintains the same measurement plane. For tracking systems, the sensor only needs to follow the tracker when the objective is to measure irradiance on the moving module plane. Adjustable measurement panels, such as those available on the XF500S-CWB, help align the sensor with the required angle.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Avoiding Shading and Choosing a Representative Measurement Point<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Buildings, trees, poles, mounting structures, and nearby equipment can block sunlight and affect readings. However, avoiding direct shading is only part of the installation decision. The sensor should also be positioned where its readings reflect the irradiance conditions of the monitored array.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For large solar farms, differences in terrain, array orientation, and local shading may require separate measurement points. A pyranometer measures irradiance at its own location, not across a fixed area, so sensor quantity and placement should follow the actual plant layout rather than an assumed coverage range.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Dew, Frost, Dust, and Snow Protection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dew and frost can reduce light transmission through the sensor dome, while dust gradually affects measurement readings. Snow may cover the sensing surface and interrupt measurements entirely.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pyranometer selection for humid, cold, or dusty sites should account for the sensor design and available accessories. Heating or ventilation may help where condensation and frost are frequent, but these options add power and maintenance requirements and are not necessary for every installation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Outdoor Protection and Electrical Safety<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For outdoor monitoring, pyranometer selection also involves checking enclosure protection, cable connections, and operating temperature range. Sealed connectors and suitable cable entries help reduce moisture-related problems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Grounding, cable shielding, and surge protection should also be considered as part of the site electrical design. An IP67 rating indicates protection against specified dust and water ingress; it does not mean the sensor is lightning-proof or more accurate. Power and signal lines may need separate surge protection depending on the installation&#8217;s exposure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For the practical setup steps, <a href=\"https:\/\/www.yantaisensor.com\/vi\/blog\/pyranometer-installation-guide\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">H\u01b0\u1edbng d\u1eabn l\u1eafp \u0111\u1eb7t pyranometer | C\u00e1ch l\u1eafp \u0111\u1eb7t \u0111\u00fang \u0111\u1ec3 \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi ch\u00ednh x\u00e1c<\/mark><\/a> covers mounting, leveling and connection checks.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-4 wp-block-gallery-7 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"5930\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-15.webp\" alt=\"Pyranometer mounted on an outdoor instrument platform\" class=\"wp-image-5930\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-15.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-15-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-15-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-15-16x12.webp 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"5927\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-12.webp\" alt=\"Irradiance monitoring equipment attached to a field mounting structure\" class=\"wp-image-5927\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-12.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-12-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-12-768x576.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/03\/pyranometer-12-16x12.webp 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"1067\" data-id=\"7374\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-4.webp\" alt=\"C\u1ea3m bi\u1ebfn th\u1eddi ti\u1ebft v\u00e0 thi\u1ebft b\u1ecb s\u1eed d\u1ee5ng n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi \u0111\u01b0\u1ee3c l\u1eafp \u0111\u1eb7t t\u1ea1i nh\u00e0 m\u00e1y \u0111i\u1ec7n m\u1eb7t tr\u1eddi\" class=\"wp-image-7374\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-4.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-4-225x300.webp 225w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-4-768x1024.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-4-9x12.webp 9w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"1067\" data-id=\"7368\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-21.webp\" alt=\"K\u1ef9 thu\u1eadt vi\u00ean ki\u1ec3m tra t\u1ee7 gi\u00e1m s\u00e1t ngo\u00e0i tr\u1eddi\" class=\"wp-image-7368\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-21.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-21-225x300.webp 225w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-21-768x1024.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-21-9x12.webp 9w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Calibration and Maintenance for Reliable Long-Term Measurements<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pyranometer selection should account for routine maintenance: keeping the sensing dome clean and checking components that may affect measurement performance. The required work depends on the instrument design and site conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Routine Cleaning and Inspection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Check the sensor dome for dust, bird droppings, water stains, or other deposits. Clean it with a soft, lint-free cloth using the method recommended by the manufacturer. Avoid abrasive materials that could scratch the dome. If the instrument has a desiccant, check its condition and replace it according to the manufacturer&#8217;s instructions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cleaning frequency depends on the site. Dusty locations may require more frequent cleaning, while areas with frequent rainfall can still develop water stains or deposits. Record cleaning dates and any maintenance work. After servicing, check that the sensor has not shifted and that its orientation still matches the intended measurement plane.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pyranometer Calibration and Data Checks<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Review the calibration certificate during pyranometer selection and again at commissioning, checking the calibration date, stated uncertainty, and traceability information. If WRR traceability is required by the project, confirm that it is explicitly documented in the certificate or supporting records.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The recalibration interval should follow the manufacturer&#8217;s recommendations and the project&#8217;s measurement uncertainty requirements. Historical calibration results can also help determine whether the interval needs to be reviewed. If readings differ unexpectedly from a properly calibrated reference instrument, first check the dome condition, sensor alignment, and data acquisition. If the discrepancy remains, arrange a calibration check and retain the results for future data review.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Calibration methods and traceability are discussed in <a href=\"https:\/\/www.yantaisensor.com\/vi\/blog\/pyranometer-calibration-standards\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">Ti\u00eau chu\u1ea9n Hi\u1ec7u chu\u1ea9n Pyranometer: Y\u00eau c\u1ea7u, Ph\u01b0\u01a1ng ph\u00e1p v\u00e0 Th\u1ef1c h\u00e0nh T\u1ed1t nh\u1ea5t theo ISO 9847<\/mark><\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-2 wp-block-gallery-8 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"3570\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-9.webp\" alt=\"Technician working beside monitoring equipment at a solar plant\" class=\"wp-image-3570\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-9.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-9-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-9-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"900\" data-id=\"3331\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-7.webp\" alt=\"Close-up of a pyranometer bubble level\" class=\"wp-image-3331\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-7.webp 1200w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-7-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-7-1024x768.webp 1024w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-Radiation-Sensors-Pyranometers-7-768x576.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Choosing the Right Pyranometer Configuration for Different Solar Projects<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pyranometer selection depends on the required measurement planes, monitoring accuracy, and other environmental data the project needs. The following configurations illustrate solar pyranometer selection for common PV applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Trang tr\u1ea1i N\u0103ng l\u01b0\u1ee3ng M\u1eb7t tr\u1eddi Quy m\u00f4 Ti\u1ec7n \u00edch<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Large solar farms may need independent GHI and POA measurements, depending on the monitoring requirements. Sensor locations should account for array layout, terrain, and shading. Pyranometer selection for a specified ISO 9060 class requires documentation confirming the instrument&#8217;s classification.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Commercial and Rooftop PV Systems<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For rooftop projects with limited installation space, an integrated PV weather sensor can collect POA irradiance, module temperature, ambient temperature, and other weather data at one location. The XF500S-CWB supports this arrangement through RS485\/Modbus RTU communication. Its standard configuration uses a TBQ-2C-D pyranometer; other pyranometer models and classifications are optional and should be confirmed against the project requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Bifacial and Tracking PV Systems<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bifacial projects may require separate measurements of front-side POA, rear-side irradiance, and albedo. For tracking systems, the sensor must follow the modules when measuring the changing POA plane. Solar pyranometer selection for these arrays must account for sensor positions and the number of measurement points.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Independent Pyranometers vs. Integrated PV Weather Sensors<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Selection factor<\/th><th>Independent pyranometer<\/th><th>Integrated PV weather sensor<\/th><\/tr><\/thead><tbody><tr><td>Measurement focus<\/td><td>Dedicated irradiance measurement<\/td><td>Irradiance and multiple weather parameters<\/td><\/tr><tr><td>C\u00e0i \u0111\u1eb7t<\/td><td>Separate sensor installation<\/td><td>Multiple sensors in one unit<\/td><\/tr><tr><td>C\u1ea5u h\u00ecnh<\/td><td>Flexible instrument selection<\/td><td>Depends on available sensor options<\/td><\/tr><tr><td>Best suited to<\/td><td>Specific irradiance and classification requirements<\/td><td>Combined PV and weather monitoring<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Choose an independent pyranometer when the project requires dedicated irradiance measurements or a specified instrument classification. An integrated PV weather sensor is more practical when several PV and weather parameters need to be collected at the same location. Base pyranometer selection on the monitoring specification, not simply the number of functions in the device.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-3 wp-block-gallery-9 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" data-id=\"3571\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-10.webp\" alt=\"C\u00e1c m\u00f4-\u0111un tham chi\u1ebfu v\u00e0 t\u1ee7 gi\u00e1m s\u00e1t t\u1ea1i nh\u00e0 m\u00e1y \u0111i\u1ec7n m\u1eb7t tr\u1eddi\" class=\"wp-image-3571\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-10.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-10-300x225.webp 300w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2025\/12\/Solar-PV-Industry-Solutions-10-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"1067\" data-id=\"7367\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-20.webp\" alt=\"K\u1ef9 thu\u1eadt vi\u00ean l\u00e0m vi\u1ec7c b\u00ean c\u1ea1nh c\u1ed9t gi\u00e1m s\u00e1t th\u1eddi ti\u1ebft t\u1ea1i nh\u00e0 m\u00e1y \u0111i\u1ec7n m\u1eb7t tr\u1eddi\" class=\"wp-image-7367\" style=\"aspect-ratio:4\/3;object-fit:contain\" srcset=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-20.webp 800w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-20-225x300.webp 225w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-20-768x1024.webp 768w, https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/06\/Kyrgyzstan-Solar-Power-Plant-Weather-Monitoring-System-Project-20-9x12.webp 9w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" data-id=\"8739\" src=\"https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/08\/TBQ%E2%80%912C-Total-Solar-Radiation-Sensor-for-Zhenfa-Pakistan-Solar-Power-Plant-768x1024.webp\" alt=\"Meteorological monitoring equipment installed at a solar project\" class=\"wp-image-8739\" style=\"aspect-ratio:4\/3;object-fit:contain\"\/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">K\u1ebft lu\u1eadn<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Knowing how to choose a pyranometer starts with three practical checks: define the measurement objective, confirm the required measurement performance, and review the installation and operating conditions. Determine whether the project needs GHI, POA, or other irradiance measurements, then check the relevant ISO 9060 classification, IEC 61724-1 requirements, signal interface, power supply, mounting position, and calibration arrangements. A suitable pyranometer for solar projects should meet the actual monitoring and acceptance requirements, rather than simply offer the highest specification.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yantai Sensor provides solar radiation sensors and integrated PV weather monitoring equipment for different project needs. Our team can help with pyranometer selection by reviewing measurement requirements, sensor specifications, communication interfaces, and installation conditions to identify a suitable configuration. <a href=\"https:\/\/www.yantaisensor.com\/vi\/lien-he-voi-chung-toi\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">Li\u00ean h\u1ec7 Yantai Sensor<\/mark><\/a> to discuss your project requirements and find the right monitoring equipment for your solar installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQs About Pyranometer Selection for Solar Projects<\/h2>\n\n\n<style>.kt-accordion-id10734-pyr-faq .kt-accordion-inner-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:10px;}.kt-accordion-id10734-pyr-faq .kt-accordion-panel-inner{border-top:0px solid transparent;border-right:0px solid transparent;border-bottom:0px solid transparent;border-left:0px solid transparent;padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-right:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);padding-left:var(--global-kb-spacing-sm, 1.5rem);}.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header{border-top:1px solid #f2f2f2;border-right:1px solid #f2f2f2;border-bottom:1px solid #f2f2f2;border-left:1px solid #f2f2f2;border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;background:#f2f2f2;color:#555555;padding-top:9px;padding-right:13px;padding-bottom:9px;padding-left:13px;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap .kt-blocks-accordion-icon-trigger:before{background:#555555;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-icon-trigger{background:#555555;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-icon-trigger:before{background:#f2f2f2;}.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header:hover, \n\t\t\t\tbody:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq .kt-blocks-accordion-header:focus-visible{color:#444444;background:#eeeeee;border-top:1px solid #878787;border-right:1px solid #878787;border-bottom:1px solid #878787;border-left:1px solid #878787;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:before, body:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-blocks-accordion--visible .kt-blocks-accordion-icon-trigger:after, body:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger:before{background:#444444;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger, body:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger{background:#444444;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:before, body:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger:after, body:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger:before{background:#eeeeee;}.kt-accordion-id10734-pyr-faq .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible,\n\t\t\t\t.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active{color:#ffffff;background:var(--global-palette1, #3182CE);border-top:1px solid #444444;border-right:1px solid #444444;border-bottom:1px solid #444444;border-left:1px solid #444444;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:before{background:#ffffff;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger{background:#ffffff;}.kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id10734-pyr-faq:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:before{background:var(--global-palette1, #3182CE);}@media all and (max-width: 1024px){.kt-accordion-id10734-pyr-faq .kt-accordion-panel-inner{border-top:0px solid transparent;border-right:0px solid transparent;border-bottom:0px solid transparent;border-left:0px solid transparent;}}@media all and (max-width: 1024px){.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header{border-top:1px solid #f2f2f2;border-right:1px solid #f2f2f2;border-bottom:1px solid #f2f2f2;border-left:1px solid #f2f2f2;}}@media all and (max-width: 1024px){.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header:hover, \n\t\t\t\tbody:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq .kt-blocks-accordion-header:focus-visible{border-top:1px solid #878787;border-right:1px solid #878787;border-bottom:1px solid #878787;border-left:1px solid #878787;}}@media all and (max-width: 1024px){.kt-accordion-id10734-pyr-faq .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible,\n\t\t\t\t.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active{border-top:1px solid #444444;border-right:1px solid #444444;border-bottom:1px solid #444444;border-left:1px solid #444444;}}@media all and (max-width: 767px){.kt-accordion-id10734-pyr-faq .kt-accordion-inner-wrap{display:block;}.kt-accordion-id10734-pyr-faq .kt-accordion-inner-wrap .kt-accordion-pane:not(:first-child){margin-top:10px;}.kt-accordion-id10734-pyr-faq .kt-accordion-panel-inner{border-top:0px solid transparent;border-right:0px solid transparent;border-bottom:0px solid transparent;border-left:0px solid transparent;}.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header{border-top:1px solid #f2f2f2;border-right:1px solid #f2f2f2;border-bottom:1px solid #f2f2f2;border-left:1px solid #f2f2f2;}.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header:hover, \n\t\t\t\tbody:not(.hide-focus-outline) .kt-accordion-id10734-pyr-faq .kt-blocks-accordion-header:focus-visible{border-top:1px solid #878787;border-right:1px solid #878787;border-bottom:1px solid #878787;border-left:1px solid #878787;}.kt-accordion-id10734-pyr-faq .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible,\n\t\t\t\t.kt-accordion-id10734-pyr-faq > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active{border-top:1px solid #444444;border-right:1px solid #444444;border-bottom:1px solid #444444;border-left:1px solid #444444;}}<\/style>\n<div class=\"wp-block-kadence-accordion alignnone\"><div class=\"kt-accordion-wrap kt-accordion-id10734-pyr-faq kt-accordion-has-8-panes kt-active-pane-0 kt-accordion-block kt-pane-header-alignment-left kt-accodion-icon-style-basic kt-accodion-icon-side-right\" style=\"max-width:none\"><div class=\"kt-accordion-inner-wrap\" data-allow-multiple-open=\"false\" data-start-open=\"none\">\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-1 kt-pane10734-pyr-1\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">T\u00f4i n\u00ean ki\u1ec3m tra nh\u1eefng g\u00ec tr\u01b0\u1edbc khi mua c\u1ea3m bi\u1ebfn \u0111o t\u1ed5ng b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">Begin pyranometer selection by defining whether the project needs GHI, POA, or another irradiance measurement. Then check the required ISO 9060 classification, measurement range, spectral response, calibration documentation, and output signal. Also confirm that the sensor is compatible with the data logger and installation conditions. These checks help avoid selecting an instrument that meets its product specifications but does not meet the project&#8217;s monitoring requirements.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-2 kt-pane10734-pyr-2\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">S\u1ef1 kh\u00e1c bi\u1ec7t gi\u1eefa c\u1ea3m bi\u1ebfn \u0111o t\u1ed5ng b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi c\u1ea5p A v\u00e0 c\u1ea5p B l\u00e0 g\u00ec?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">Theo ISO 9060:2018, c\u00e1c b\u1ee9c x\u1ea1 k\u1ebf to\u00e0n ph\u1ea7n Lo\u1ea1i A v\u00e0 Lo\u1ea1i B \u0111\u01b0\u1ee3c ph\u00e2n bi\u1ec7t d\u1ef1a tr\u00ean nhi\u1ec1u ti\u00eau ch\u00ed hi\u1ec7u n\u0103ng, bao g\u1ed3m th\u1eddi gian \u0111\u00e1p \u1ee9ng, \u0111\u1ed9 \u1ed5n \u0111\u1ecbnh, \u0111\u00e1p \u1ee9ng theo h\u01b0\u1edbng v\u00e0 \u0111\u00e1p \u1ee9ng theo nhi\u1ec7t \u0111\u1ed9. Lo\u1ea1i A c\u00f3 y\u00eau c\u1ea7u kh\u1eaft khe h\u01a1n \u0111\u1ed1i v\u1edbi c\u00e1c ti\u00eau ch\u00ed ph\u00e2n lo\u1ea1i, nh\u01b0ng kh\u00f4ng n\u00ean quy hai lo\u1ea1i n\u00e0y v\u1ec1 c\u00e1c t\u1ef7 l\u1ec7 ph\u1ea7n tr\u0103m \u0111\u1ed9 ch\u00ednh x\u00e1c c\u1ed1 \u0111\u1ecbnh. Khi l\u1ef1a ch\u1ecdn b\u1ee9c x\u1ea1 k\u1ebf to\u00e0n ph\u1ea7n, c\u1ea7n xem x\u00e9t t\u00e0i li\u1ec7u ph\u00e2n lo\u1ea1i v\u00e0 c\u00e1c th\u00f4ng s\u1ed1 hi\u1ec7u n\u0103ng ri\u00eang c\u1ee7a nh\u1eefng thi\u1ebft b\u1ecb \u0111\u01b0\u1ee3c so s\u00e1nh.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-3 kt-pane10734-pyr-3\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">Trang tr\u1ea1i \u0111i\u1ec7n m\u1eb7t tr\u1eddi c\u00f3 c\u1ea7n c\u1ea3m bi\u1ebfn \u0111o t\u1ed5ng b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi c\u1ea5p A kh\u00f4ng?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">Not necessarily. The required class depends on the monitoring system category, project specifications, and intended use of the irradiance data, rather than the solar farm&#8217;s installed capacity alone. Base pyranometer selection on the applicable IEC 61724-1 requirements and contract documents. If a specific ISO 9060 class is required, make sure the instrument&#8217;s supporting documentation confirms that classification.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-4 kt-pane10734-pyr-4\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">Thi\u1ebft b\u1ecb n\u00e0o t\u1ed1t h\u01a1n cho gi\u00e1m s\u00e1t quang \u0111i\u1ec7n: C\u1ea3m bi\u1ebfn b\u1ee9c x\u1ea1 t\u1ed5ng nhi\u1ec7t \u0111i\u1ec7n hay silicon?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">Nhi\u1ec7t x\u1ea1 k\u1ebf s\u1eed d\u1ee5ng c\u1eb7p nhi\u1ec7t \u0111i\u1ec7n li\u00ean ho\u00e0n c\u00f3 \u0111\u00e1p \u1ee9ng ph\u1ed5 r\u1ed9ng v\u00e0 th\u01b0\u1eddng \u0111\u01b0\u1ee3c s\u1eed d\u1ee5ng \u0111\u1ec3 \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi. C\u1ea3m bi\u1ebfn silicon th\u01b0\u1eddng c\u00f3 t\u1ed1c \u0111\u1ed9 \u0111\u00e1p \u1ee9ng nhanh h\u01a1n nh\u01b0ng bao ph\u1ee7 d\u1ea3i ph\u1ed5 h\u1eb9p h\u01a1n v\u00e0 c\u00f3 th\u1ec3 ch\u1ecbu \u1ea3nh h\u01b0\u1edfng l\u1edbn h\u01a1n t\u1eeb nh\u1eefng thay \u0111\u1ed5i trong ph\u1ed5 b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi. Kh\u00f4ng c\u00f3 c\u00f4ng ngh\u1ec7 n\u00e0o v\u01b0\u1ee3t tr\u1ed9i trong m\u1ecdi tr\u01b0\u1eddng h\u1ee3p. Khi l\u1ef1a ch\u1ecdn nhi\u1ec7t x\u1ea1 k\u1ebf \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi, h\u00e3y so s\u00e1nh \u0111\u00e1p \u1ee9ng ph\u1ed5, y\u00eau c\u1ea7u \u0111o l\u01b0\u1eddng v\u00e0 c\u00e1c th\u00f4ng s\u1ed1 hi\u1ec7u su\u1ea5t c\u1ee7a t\u1eebng lo\u1ea1i.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-5 kt-pane10734-pyr-5\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">B\u1ee9c x\u1ea1 POA c\u00f3 quan tr\u1ecdng h\u01a1n GHI trong gi\u00e1m s\u00e1t t\u1ea5m pin m\u1eb7t tr\u1eddi kh\u00f4ng?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">Trong gi\u00e1m s\u00e1t hi\u1ec7u su\u1ea5t h\u1ec7 th\u1ed1ng \u0111i\u1ec7n m\u1eb7t tr\u1eddi (PV), b\u1ee9c x\u1ea1 tr\u00ean m\u1eb7t ph\u1eb3ng m\u00f4-\u0111un (POA) th\u01b0\u1eddng li\u00ean quan tr\u1ef1c ti\u1ebfp h\u01a1n v\u00ec \u0111\u1ea1i l\u01b0\u1ee3ng n\u00e0y \u0111o b\u1ee9c x\u1ea1 m\u1eb7t tr\u1eddi tr\u00ean m\u1eb7t ph\u1eb3ng c\u1ee7a c\u00e1c m\u00f4-\u0111un. T\u1ed5ng b\u1ee9c x\u1ea1 tr\u00ean m\u1eb7t ph\u1eb3ng ngang (GHI) \u0111o b\u1ee9c x\u1ea1 tr\u00ean b\u1ec1 m\u1eb7t n\u1eb1m ngang v\u00e0 h\u1eefu \u00edch cho vi\u1ec7c \u0111\u00e1nh gi\u00e1 t\u00e0i nguy\u00ean n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi v\u00e0 gi\u00e1m s\u00e1t th\u1eddi ti\u1ebft. Nhi\u1ec1u d\u1ef1 \u00e1n c\u00f3 th\u1ec3 t\u1eadn d\u1ee5ng c\u1ea3 hai ph\u00e9p \u0111o. GHI v\u00e0 POA t\u01b0\u01a1ng \u1ee9ng v\u1edbi c\u00e1c m\u1eb7t ph\u1eb3ng \u0111o kh\u00e1c nhau, v\u00ec v\u1eady kh\u00f4ng n\u00ean s\u1eed d\u1ee5ng \u0111\u1ea1i l\u01b0\u1ee3ng n\u00e0y \u0111\u1ec3 thay th\u1ebf tr\u1ef1c ti\u1ebfp cho \u0111\u1ea1i l\u01b0\u1ee3ng kia.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-6 kt-pane10734-pyr-6\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">N\u00ean hi\u1ec7u chu\u1ea9n l\u1ea1i b\u1ee9c x\u1ea1 k\u1ebf t\u1ed5ng bao l\u00e2u m\u1ed9t l\u1ea7n?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">The calibration interval depends on the manufacturer&#8217;s recommendations, project requirements, site conditions, and historical calibration results. There is no universal interval for all pyranometers. Check the calibration date and stated uncertainty when commissioning the instrument, then follow the agreed quality management plan. Regular cleaning and inspection help maintain measurement conditions but cannot replace recalibration.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-7 kt-pane10734-pyr-7\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">Which Output Signal Should I Choose for a Solar Pyranometer?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">Choose an output that matches the data logger or monitoring system. Thermopile instruments commonly provide millivolt outputs, while some integrated sensors support voltage, 4\u201320 mA, or RS485\/Modbus RTU. Include the input type, cable distance, power supply, and communication protocol in your pyranometer selection checks before ordering. This helps prevent signal incompatibility and avoids unnecessary converters or additional data acquisition hardware.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-8 kt-pane10734-pyr-8\"><div class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\">When Should I Choose an Integrated PV Weather Station Instead of a Standalone Pyranometer?<\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/div><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<p class=\"wp-block-paragraph\">An integrated PV weather station is practical when a project needs irradiance, module temperature, ambient temperature, and other weather parameters collected at one location. A standalone pyranometer offers more flexibility when dedicated irradiance measurements or specific instrument classifications are required. For pyranometer selection, verify the integrated station&#8217;s standard sensor configuration, optional upgrades, and compliance with the project&#8217;s monitoring requirements.<\/p>\n<\/div><\/div><\/div>\n<\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Compare measurement objectives, pyranometer technologies, ISO classifications, installation requirements and calibration arrangements for solar projects.<\/p>","protected":false},"author":1,"featured_media":10752,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[11],"tags":[],"class_list":["post-10734","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"taxonomy_info":{"category":[{"value":11,"label":"Blog"}]},"featured_image_src_large":["https:\/\/www.yantaisensor.com\/wp-content\/uploads\/2026\/11\/How-to-Choose-a-Pyranometer-for-Solar-Projects.webp",800,600,false],"author_info":{"display_name":"admin","author_link":"https:\/\/www.yantaisensor.com\/vi\/author\/admin"},"comment_info":0,"category_info":[{"term_id":11,"name":"Blog","slug":"blog","term_group":0,"term_taxonomy_id":11,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","cat_ID":11,"category_count":135,"category_description":"","cat_name":"Blog","category_nicename":"blog","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/posts\/10734","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/comments?post=10734"}],"version-history":[{"count":8,"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/posts\/10734\/revisions"}],"predecessor-version":[{"id":10753,"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/posts\/10734\/revisions\/10753"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/media\/10752"}],"wp:attachment":[{"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/media?parent=10734"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/categories?post=10734"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yantaisensor.com\/vi\/wp-json\/wp\/v2\/tags?post=10734"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}